• Formulating Thermal Management Materials for AI Data Centres: Coolants, TIMs, Encapsulants and Reliability

    Advanced training on coolants, TIMs, encapsulants and adhesives for AI data centres, covering formulation, compatibility and reliability.

6 Month Access

Get full access to the complete training for 6 months

Training Certificate

Demonstrate your expertise with a subject-specific training certificate

Training Materials

Download training materials including presentation slides, Q&A, and FAQ PDFs

Expert Connect

Connect with the expert via discussion forum to clarify technical questions

Heat densities in AI data centres have outrun what conventional cooling was built for. Rack power is pushing past 100 kW, and air cooling has hit its ceiling.

AI data-centre cooling is no longer only a mechanical-engineering problem. Coolant chemistry, thermal-interface formulation, filler loading, dielectric behaviour, corrosion control, material compatibility, and long-term reliability now determine whether high-power electronic systems remain stable in operation.


Most materials look great on a data sheet. Fewer survive the field: corrosion, pump-out, bleed, filler settling, elastomer swelling, dielectric drift, and moisture uptake. The fluid supply chain itself is also shifting, with 3M’s exit from PFAS manufacturing disrupting several chemistries historically used in immersion cooling.


This expert-led training covers the four material groups now critical to high-power computing: direct-to-chip coolants, immersion-cooling dielectric fluids, thermal interface materials, and protective materials including gap fillers, encapsulants, underfills, and thermally conductive adhesives. Built for thermal-management formulators, electronic-material R&D teams, coolant developers, and silicone and adhesive chemists who need to know how to actually select, formulate, test, and qualify these materials, not just specify them.


No infrastructure theory. No AI hardware overview. Just the formulation science behind materials that hold up in the field, not only in testing.


Why Not To Miss This Training

AI data-centre material development is moving faster than most formulation teams are prepared for. This training helps you build the technical judgement needed to evaluate these systems before costly formulation, qualification, or field failures occur.

  • AI Cooling Is Changing Fast: Materials are now central to system performance and reliability.
  • Data Sheets Are Not Enough: Real operating conditions expose weaknesses conventional testing may miss.
  • Material Choices Are Interdependent: Coolants, TIMs, fillers, and protective systems must work together.
  • Legacy Chemistries Are Shifting: Formulators need clearer options for emerging fluid and material platforms.
  • Qualification Expectations Are Rising: Faster development still requires defensible technical decisions.
  • Early Expertise Creates Advantage: Build capability before this market becomes crowded and highly competitive.


Who should attend

  • Thermal-management material formulators

  • Silicone and adhesive R&D chemists

  • Heat-transfer-fluid developers

  • Electronic-material product developers

  • Encapsulant and underfill specialists

  • Filler and additive suppliers

  • Application-development scientists

  • Electronics reliability engineers

  • Technical service teams

  • Data-centre coolant suppliers

  • Product and innovation managers


Training Outline:

In this training expert will discuss the following topics in details:

  • Where Materials Sit in AI Cooling Architectures

    • Quick map across air, hybrid, direct-to-chip, and immersion cooling architectures

    • Shows exactly where coolant, TIM, and encapsulant chemistry earns or loses its keep

    • Sets up the framework the rest of the training builds on

  • Direct-to-Chip Coolant Formulation

    • Base fluid platforms and corrosion inhibitor design

    • Copper and elastomer compatibility issues that decide five-year life versus eighteen-month failure

    • The deepest technical section of the training

  • Immersion-Cooling Dielectric Fluids

    • Single-phase and two-phase fluid chemistry and dielectric behaviour

    • The substitution question every immersion program now faces since 3M exited PFAS manufacturing

    • What to evaluate before locking in a fluid platform

  • Thermal Interface Materials and Gap Fillers

    • Filler systems and bond-line control

    • Why TIMs fail after they've already passed qualification: pump-out, bleed, dry-out, migration

    • Why high thermal conductivity on a data sheet means nothing without field reliability

  • Encapsulants, Underfills, and Protective Materials

    • CTE control, moisture management, and cure stress

    • Treating encapsulants, underfills, and TIMs as one coordinated stack, not separate specs

    • Where package-level failures actually originate

  • Qualification and Failure Diagnosis

    • Building a reliability data package that actually holds up

    • Tracing a field failure back to root cause instead of guessing

    • AI Data-Centre Thermal Material Qualification Matrix

  • Q&A Session to Clear Doubts


What You Walk Away With

The AI Data-Centre Thermal Material Qualification Matrix, ready to apply to your own material shortlist immediately, plus the judgment to actually use it: tracing a failure back to root cause instead of guessing, and knowing where the fluid supply chain is heading before your next sourcing decision.

Trainers List

Training Curriculum

Get Started Now!

Related Trainings